Model | 6605 | 6610 | 6620 | 6640 |
INPUT |
Phase | 1 Phase |
Voltage | 110/220Vac±10% |
Frequency | 47-63Hz |
OUTPUT |
AC |
Power rating | 500VA | 1000VA | 2000VA | 4000VA |
Max. Current (r.m.s)*1 | 0-150V | 4.6A | 9.2A | 18.4A | 36.8A |
0-300V | 2.3A | 4.6A | 9.2A | 18.4A |
Max. Current(peak) | 0-150V | 13.8A | 27.6A | 55.2A | 110.4A |
0-300V | 6.9A | 13.8A | 27.6A | 55.2A |
Phase | 1Phase / 2W |
Total Harmonic Distortation (T.H.D) | <0.5% at 40 - 100Hz , <1% at 101-500Hz (Resistive Load) |
Crest Factor | >= 3 |
Line Regulation | ± 0.1V |
Load Regulation | ±(0.5% of output +0.5V) at Resistive Load |
Response Time | <400µS |
SETTING |
Voltage | Range | 0-300V, 150V/300V Auto Range |
Resolution | 0.1V |
Accuracy | ±(1% of setting + 2counts) |
Frequency | Range | 40-500Hz Full Range Adjust |
Resolution | 0.1Hz at 40.0-99.9Hz , 1Hz at 100-500Hz |
Accuracy | ±0.03% of setting |
Starting& Ending Phase Angle | Range | 0-360° |
Resolution | 1° |
Accuracy | ±1°(45 - 65HZ) |
DC(Optioin) |
MAX. Power | 250W | 500W | 1KW | 2KW |
Max. Current | 0-200V | 2.3A | 4.6A | 9.2A | 18.4A |
0-400V | 1.15A | 2.3A | 4.6A | 9.2A |
SETTING |
Voltage | Range | 0-200V / 0-400V Selectable |
Resolution | 0.1V |
Accuracy | ±(1% of setting + 2counts) |
Ripple and Noise (RMS) | Range : 0-200V <250mV Range : 0-400V <400mV | Range : 0-200V<350mV Range : 0-400V<550mV |
Ripple and Noise (p-p) | <2Vp-p | <3.0Vp-p |
MEASUREMENT |
Voltage (AC & DC) | Range | 0.0-400.0V |
Resolution | 0.1V |
Accuracy | ±(1% of reading + 2counts) |
Frequency | Range | 0.0-500.0Hz |
Resolution | 0.1Hz |
Accuracy | ±0.1Hz |
Current (rms) (AC & DC) | Range | L | 0.005A - 0.600A | 0.005A - 1.200A | 0.005A - 2.400A | - |
H | 0.50A -6.50A | 1.00A -13.00A | 2.00A -26.00A | 0.00 - 52.00A |
Resolution | L | 0.001A |
H | 0.01A |
Accuracy | L | ±(1% of reading +5counts) |
H | ±(1% of reading +5counts) |
Current(peak) | Range | 0.0 - 19.0A | 0.0 - 76.0A | 0.0 - 152.0A | - |
Resolution | 0.1A |
Accuracy | ±(1% of reading + 5counts) |
Power | Range | L | 0.0W - 60.0W | 0.0W - 120.0W | 0.0W - 240.0W | - |
H | 50W -650W | 100W -1300W | 200W -2600W | 0 - 5200W |
Resolution | L | 0.1W |
H | 1W |
Accuracy | L | ±(2% of reading +5counts) |
H | ±(2% of reading +2counts) |
Power Factor | Range | 0.000-1.000 |
Resolution | 0.001 |
Accuracy | W / VA ,Calculated and displayed to three significant digits |
GENERAL |
Remote Input Signal Interface(Option) | Test, Reset, Recall memory 1 through 7 |
Remote Output Signal | Pass, Fail ,Test-in Process |
Memory | 50 memories, 9 steps/memory |
Sync Output Signal | DC Level 5V |
Timer | 0=Continuous, 0.5-999.9 (Unit: sec, minute, hour selectable) |
Alarm Volume Setting | Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. |
Graphic Display | 240 x 64 dot resolution Monographic LCD /Contrast 9 Levels 1-9 |
Auto loop cycle | 0=Continuous, OFF, 2~9999 |
Over Current Fold Back | On/Off , Setting On when output current over setting Hi-A value it will fold back output voltage to keep constant output current is setting Hi-A value. |
High / Low Limit Protection | Arms, Apeak, P, PF |
Protection | OCP, OVP, OPP, OTP |
Efficiency | ≥80%(at Full Load ) |
Interface (Option) | GPIB / RS232, PLC Remote Input Card |
Operation Environment | 0-40?C/20-80%RH |
Dimension(HxD) mm | 430 x 89 x 400 | 430 x 89 x 400 | 430 x 89 x 500 | 430 x 222 x 500 |
Net Weight | 16.5Kg | 18.2Kg | 30Kg | 65Kg |